How to Set Section Types at Runtime
Jump to navigation
Jump to search
Section Type Column
Upon Run Start
Section Type Column
In your Track Network Details table, there is a column called "Section Type".
If this column is found, Planimate® uses it to read/set the track network section types.
- The units format in this column should be set to the "_section type" label list, so you can use it to specify section types across the network.
- The default/clear value for this column should be the "-" label (which equates to zero) so that existing networks are properly set up in the table.
Upon Run Start
When the run starts, Planimate® will treat the column as follows:
- If the value is "-" then Planimate® will read the section type as-is from the track network.
- If the value is not "-" then Planimate® will ensure the section is changed to the value in the table when the run is started.