Order of Run Start Broadcasts: Difference between revisions

From Planimate Knowledge Base
Jump to navigation Jump to search
No edit summary
m (changed list to numbered list)
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
<font face="Arial"><br /> Currently the following happens and PL sends the following BC sequence<br /> when a run is started:
Currently the following happens and PL sends the following BC sequence when a run is started:
 


START RUN ENGINE:
START RUN ENGINE:
*The model is initialised for run (phase 1)<br /> BC _Preinit Start<br /> BC _Model loaded (if its an initial run)<br /> BC _PreInit End
#The model is initialised for run (phase 1)
*The model is initialised for run (phase 2)<br /> GC _Run Start
#BC _Preinit Start
*model pauses or continues depending on options
#BC _PreInit End
 
#BC _Model loaded (if its an initial run)
 
#The model is initialised for run (phase 2)
The 2 stage init process was from an era when certain objects could not<br /> be changed once the run was going but the modeller needed an ability to<br /> initially set them up. (the conveyor is still like this). Also item "preloading" happens in the<br /> second phase of the initialisation of the run.
#BC _Run Start
 
#model pauses or continues depending on options
 
Two changes I'd like to make:
*move the _Model Loaded BC to occur just before _Run Start. This will allow it to trigger messages, etc. which it cant at the current time it<br /> is sent
*reduce use and eventually eliminate dependence on the 2 _PreInit<br /> broadcasts by modellers.
 
 
(followup: these BCs wont be removed as they are useful for modeller's setup use)<br />


The 2 stage init process was from an era when certain objects could not be changed once the run was going but the modeller needed an ability to initially set them up.


</font>
----
----


Line 26: Line 18:
<font size="2">idkbase note 205</font>
<font size="2">idkbase note 205</font>


[[Category:Broadcast/System]]
[[Category:Broadcast]]
[[Category:Runtime Engine]]
[[Category:Runtime Engine]]
[[Category:FAQ]]
[[Category:FAQ]]

Latest revision as of 11:05, 13 January 2008

Currently the following happens and PL sends the following BC sequence when a run is started:

START RUN ENGINE:

  1. The model is initialised for run (phase 1)
  2. BC _Preinit Start
  3. BC _PreInit End
  4. BC _Model loaded (if its an initial run)
  5. The model is initialised for run (phase 2)
  6. BC _Run Start
  7. model pauses or continues depending on options

The 2 stage init process was from an era when certain objects could not be changed once the run was going but the modeller needed an ability to initially set them up.