How to Set Section Types at Runtime: Difference between revisions
Jump to navigation
Jump to search
Section Type Column
Upon Run Start
mNo edit summary |
mNo edit summary |
||
Line 1: | Line 1: | ||
== Section Type Column<br> == | == Section Type Column<br> == | ||
In your Track Network Details table, there is a column called "<u>'''Section Type'''</u>". | In your Track Network Details table, there is a column called "<u>'''Section Type'''</u>". | ||
If this column is found, Planimate® uses it to read/set the track network section types. | If this column is found, Planimate® uses it to read/set the track network section types. | ||
*The units format in this column should be set to the "_section type" label list, so you can use it to specify section types across the network. | *The units format in this column should be set to the "_section type" label list, so you can use it to specify section types across the network. | ||
*The default/clear value for this column should be the "-" label (which equates to zero) so that existing networks are properly set up in the table. | *The default/clear value for this column should be the "-" label (which equates to zero) so that existing networks are properly set up in the table. | ||
== Upon Run Start<br> == | == Upon Run Start<br> == | ||
When the run starts, Planimate® will treat the column as follows: | When the run starts, Planimate® will treat the column as follows: | ||
*If the value is "-" then Planimate® will read the section type as-is from the track network. <br> | *If the value is "-" then Planimate® will read the section type as-is from the track network. <br> | ||
*If the value is not "-" then Planimate® will ensure the section is changed to the value in the table when the run is started.<br><br> | *If the value is not "-" then Planimate® will ensure the section is changed to the value in the table when the run is started.<br><br> | ||
[[Category: | [[Category:Track]] |
Latest revision as of 11:27, 9 May 2011
Section Type Column
In your Track Network Details table, there is a column called "Section Type".
If this column is found, Planimate® uses it to read/set the track network section types.
- The units format in this column should be set to the "_section type" label list, so you can use it to specify section types across the network.
- The default/clear value for this column should be the "-" label (which equates to zero) so that existing networks are properly set up in the table.
Upon Run Start
When the run starts, Planimate® will treat the column as follows:
- If the value is "-" then Planimate® will read the section type as-is from the track network.
- If the value is not "-" then Planimate® will ensure the section is changed to the value in the table when the run is started.