Search results

Jump to navigation Jump to search
  • A [[system attribute]] limits how deep PL will scan a spatial net looking for the closest route to the target. ...t route at all (if it has too many<br /> intermediate nodes) in which case PL will report a flow error.
    1 KB (244 words) - 13:43, 12 January 2008
  • ...ey are ready to reuse. I may have to do this for portals etc. but it makes PL less stable as its somewhat messy. ...d should differ by 3276 or so. Always check this on exitting PL as it will help identify a leak.
    1 KB (228 words) - 22:29, 12 January 2008
  • '''Keyword:''' pl "pl <search term>" (without quotes)
    1 KB (201 words) - 09:42, 10 July 2008
  • [[File:PL main screen work area.png]] [[File:PL main screen tool menu.png]]
    2 KB (282 words) - 10:45, 1 March 2016
  • PL will revert to using the default font if the font selected matches the defa
    348 bytes (56 words) - 14:51, 12 January 2008
  • Limits how deep PL will scan a spatial net looking for the closest route to the target. In other words, reducing the search depth may cause PL to chose a route which is not the "shortest".
    3 KB (538 words) - 10:17, 5 January 2009
  • Build notes for iFlow, PL and IDBase<font face="Arial"> ...moved to iFlow so there are new<br /> modules there and some removed form PL and IDBase KB projects
    4 KB (721 words) - 20:06, 13 January 2008
  • Currently the following happens and PL sends the following BC sequence when a run is started:
    626 bytes (101 words) - 11:05, 13 January 2008
  • *Dont start a name with an underscore unless PL has defined it for you (eg: item attributes sent by broadcasts) Lists that are regular label lists but provided for you by PL are named with a leading underscore and a lower case name. For example _col
    2 KB (367 words) - 16:18, 13 July 2011
  • This is intended to help modellers secure their models from copying. Limits how deep PL will scan a spatial net looking for the closest route to the target.
    4 KB (738 words) - 11:22, 15 August 2016
  • ...d"<br /> The solution is to use the following script in the ODBC object in PL:
    1 KB (146 words) - 02:43, 13 January 2008
  • Numbers in PL are represented using C double precision values (64 bit). <br> Given that the hourly rate for the pipe is known, PL adjusts the transfer amount per sample to a value which takes less precisio
    3 KB (517 words) - 15:54, 23 January 2009
  • In these examples '''pl.exe''' means a standard developer EXE and '''pba.exe''' means a compiled Pl '''pl.exe modelname'''
    8 KB (1,311 words) - 16:56, 21 November 2011
  • ...1 during a run AND the "Restart When Model Stops" option is enabled, then PL will attempt to restart the model if a model error occurs. ...a modeller managing multiple runs of a network directly rather than using PL's inbuilt mechanism).
    7 KB (1,133 words) - 22:12, 4 January 2009
  • With this option on, PL doesn't read data past the rows already present in the table. Causes PL to not return to the default directory when a browser is used in a change o
    5 KB (833 words) - 00:05, 27 July 2021
  • *Start/stop/pause/close PL using the PL_Run() function *Re-loading a model in a given PL instance (without unloading the instance)
    16 KB (2,519 words) - 13:39, 2 April 2014
  • ...w an internal class to be selected. If the module only has one class, then PL will create a mapping automatically without prompting the user. This simpli
    6 KB (929 words) - 11:01, 3 April 2009
  • ...ncluding labels). This can assist in moving "report" type tables back into PL.
    2 KB (359 words) - 13:21, 5 August 2011
  • Numbers in PL are represented using C double precision values (64 bit).These have a preci ...erval To Reduce Errors". Given that the hourly rate for the pipe is known, PL adjusts the transfer amount per sample to a value which takes less precisio
    5 KB (886 words) - 15:19, 12 January 2008
  • | Logical equal (values follow PL's equality check rules) .... 'name' can be FALSE, NO or OFF for 0 and TRUE, YES or ON for 1. This can help make code intent clearer without any impact on performance in looking up a
    8 KB (1,185 words) - 18:04, 22 April 2010
  • *Iteration/ifs/whiles will tend to have a large time since PL is spending<br /> a lot of time processing within them. The results are cum
    3 KB (507 words) - 22:19, 10 January 2008
  • For advanced configurations, an internal name in PL can include the bar symbol "|"
    4 KB (650 words) - 19:26, 12 February 2008
  • This makes it easier for new users of PL to work with blocking switches and routines.
    4 KB (621 words) - 19:12, 16 January 2009
  • ...and subsequent rows increase until the final row which must have a 1.0.<br>PL&nbsp;uses a uniform (0..1) draw and locates the row where that probability
    5 KB (726 words) - 17:11, 29 June 2010
  • When this option is selected PL will automatically resize the work area of the panel to fit the window spac
    5 KB (802 words) - 02:09, 2 March 2009
  • * last pl error menu shortcut
    5 KB (751 words) - 20:08, 13 January 2008
  • This forces PL to send the BC immediately rather than waiting until a "safer" time.
    5 KB (858 words) - 22:24, 4 January 2009
  • ...he same value as the previous block. Many blocks can use the same _nodeid, PL will always search for the most recent block (not including the current).
    8 KB (1,398 words) - 12:17, 26 July 2012
  • Modellers should use this mode only where absolutely necessary as PL will not identify the dispatcher as a broadcast source since the type of br
    17 KB (2,904 words) - 11:19, 31 July 2009
  • ...cell-by-cell basis (including different label lists). With this option on, PL doesn't read data past the rows already present in the table.
    27 KB (4,757 words) - 13:46, 12 December 2008
  • ...this is potentially very slow. Icon Name should not include any extention, PL will search DBs for it. Open a HTML help window. Help File can be empty for default.
    89 KB (11,746 words) - 15:08, 14 September 2020